Potterton Fault Code

Potterton E160 Fault Code

The E160 fault is triggered when the Potterton PCB cannot confirm the fan is running at the correct speed, or the air pressure switch has not triggered during the fan proving sequence. The boiler refuses to ignite until flue clearance is confirmed safe. A Gas Safe engineer is required for diagnosis and repair.

✓ Gas Safe Reg. 919881 ✓ 24/7 cover ✓ Fixed price
[Image placeholder: Potterton boiler display showing E160 fault code — replace with professional on-site photo]

What is the Potterton E160 fault code?

The Potterton E160 fault is triggered when the control board does not receive confirmation from the air pressure switch (APS) within the expected time after the fan starts. The APS proves flue gases can escape safely before ignition is permitted. Without this confirmation, the boiler locks out. The fault can originate at the fan motor, APS, the connecting hose, the flue terminal, or the condensate system. Because Potterton shares the BDR Thermea platform with Baxi, the E160 code, fan components, and APS are the same across both brands.

Affected models
Potterton Titanium 28 HE CombiPotterton Gold 28 HE CombiPotterton Promax 28 HEPotterton Performa 28Potterton Ace 28
[Image placeholder: Potterton fan assembly and air pressure switch — replace with engineer diagnostic photo]

What causes the E160 fault?

1
Fan motor failure

A failing motor runs too slowly to generate sufficient flue draught for the APS to confirm clearance. Common on Potterton boilers over 10 years old.

2
Blocked flue terminal

A bird nest, debris, or obstruction at the flue outlet restricts airflow. E160 triggers even if the fan is running correctly.

3
Air pressure switch failure

A cracked APS diaphragm or failed contacts show E160 even when the fan is running at full speed.

4
APS hose split or disconnected

A cracked or loose hose between the APS and fan assembly prevents the switch from detecting fan pressure.

5
Blocked condensate trap

A blocked condensate trap creates backpressure in the flue gas path, mimicking a blocked flue and triggering E160.

6
Frozen condensate pipe

In cold weather, ice blocks the condensate drain — creating the same backpressure effect. E160 resolves immediately once thawed.

What you can safely check yourself

1
Check the flue terminal

If safely visible from the ground or an accessible window, inspect the flue terminal for obvious blockages. Do not reach inside the terminal or attempt to clear it at height.

2
Thaw the condensate pipe in winter

In cold weather, pour warm (not boiling) water over the external condensate pipe until it drains freely. Then attempt one reset.

3
Single reset attempt

Hold the reset button for 3 seconds. Listen for the fan starting within 5 seconds of reset. If E160 returns, call a Gas Safe engineer.

Do not reset the boiler more than once if the fault code returns immediately. Repeated resets without diagnosis can mask a worsening fault.

What needs a Gas Safe engineer

  • Test fan motor speed and current draw
  • Inspect flue terminal and full flue run for blockages
  • Test air pressure switch continuity at rest and under pressure
  • Inspect APS hose for splits, kinks, or loose connections
  • Clear or replace a blocked condensate trap
  • Check PCB fan control circuit if all other components test correctly

Many properties in Wandsworth, Merton, Lewisham, Lambeth, Southwark, Greenwich, and Bromley run Potterton Gold and Promax boilers 10–15 years old — within the fan motor wear window. The failure pattern mirrors Baxi exactly, since the same fan assembly is used across both brands. Annual servicing includes a fan speed check to catch degradation before it causes E160 lockout.

[Image placeholder: Gas Safe engineer testing Potterton fan speed and APS — replace with Reion on-site photo]

How much does a E160 repair cost?

Costs below are UK averages. Reion provides a fixed quote after the £80 diagnostic visit — no obligation to proceed.

Diagnostic visit £80
Fan motor replacement £200–£380
Air pressure switch replacement £80–£160
APS hose replacement £40–£80
Condensate trap clear/replace £60–£100

How to reset a Potterton boiler showing E160

1

In winter: thaw the condensate pipe with warm water before resetting.

2

Check the flue terminal for visible blockages.

3

Hold the reset button for 3 seconds.

4

Listen for the fan starting within 5 seconds.

5

If E160 returns, call a Gas Safe engineer.

Fan replacement runs £200–£380 on a Potterton boiler. On a Gold or Titanium model under 10 years old, fan replacement is straightforwardly worth doing. Because Potterton shares the BDR Thermea platform with Baxi, fan motors are widely available and Reion carries common sizes.

Common questions about the Potterton E160 fault

What does a Potterton E160 fault code mean?
E160 means the PCB did not receive confirmation from the air pressure switch that the fan is running correctly and the flue is clear. Most common causes are a failing fan motor, blocked flue terminal, faulty APS, or — in winter — a frozen condensate pipe.
Is the Potterton E160 the same as Baxi E160?
Yes. Because Potterton and Baxi share the BDR Thermea group engineering platform, the E160 code means the same fan and flue proving fault on both brands. Fan motors and APS components are shared across many models.
Can I fix a Potterton E160 fault myself?
A homeowner can check the flue terminal for obvious blockages and thaw a frozen condensate pipe in cold weather. All other diagnosis and repair requires a Gas Safe engineer.
Why does my Potterton boiler show E160 in cold weather?
A frozen condensate pipe creates backpressure that prevents the APS from making contact. Thawing the external condensate pipe with warm water resolves this immediately.
How much does a Potterton E160 repair cost in London?
Diagnostic visit £80. Fan motor replacement £200–£380. Air pressure switch £80–£160. APS hose £40–£80. Condensate trap £60–£100. Reion covers Wimbledon, Wandsworth, Merton, Lewisham, Lambeth, Southwark, Greenwich, Bromley, and North Surrey.

Need a Potterton engineer in London?

Reion is Gas Safe registered (919881), based in South London, and available 24/7. Fixed price after the diagnostic visit — no hidden charges.

Accreditations & qualifications
Gas Safe Register — Reg. No. 919881
City & Guilds of London Institute
Vaillant
Trustpilot
Yell
Gas Safe Register — Reg. No. 919881
City & Guilds of London Institute
Vaillant
Trustpilot
Yell