Ferroli Fault Code

Ferroli A06 Fault Code

The A06 fault means the boiler's PCB cannot confirm the fan is running at the correct speed, or the air pressure switch (APS) has failed to trigger during the flue proving sequence. The boiler refuses to ignite as a flue safety measure.

✓ Gas Safe Reg. 919881 ✓ 24/7 cover ✓ Fixed price
[Image placeholder: Ferroli boiler display showing A06 fault code — replace with professional on-site photo]

What is the Ferroli A06 fault code?

The Ferroli A06 fault is triggered when the control board does not receive confirmation from the air pressure switch (APS) after the fan starts. The APS is a safety device that monitors the differential pressure created by the fan — it proves that the flue is clear and exhaust gases can safely escape before ignition is permitted. If the APS does not confirm correct fan speed and flue clearance, A06 is displayed and ignition is blocked. The fault can lie with the fan motor, the APS diaphragm, the connecting hose, a blocked flue, or the PCB. Note: Ferroli fan motors and APS components can have a 3–7 day parts lead time from specialist suppliers.

Affected models
Ferroli Modena 32CFerroli DOMIproject 30Ferroli DOMIcompact 28Ferroli BlueHelix TECH 28CFerroli Tempra 30
[Image placeholder: Ferroli fan motor and air pressure switch assembly — replace with engineer diagnostic photo]

What causes the A06 fault?

1
Fan motor failure

The fan motor degrades over time and may run too slowly to generate sufficient flue draught for the APS to trigger. Fan failure is the most common cause of A06 on older Ferroli units.

2
Blocked flue terminal

A bird nest, debris, or partially obstructed flue will restrict airflow and prevent the APS from making — even if the fan is running at full speed.

3
Air pressure switch failure

A cracked APS diaphragm or failed contacts mean the switch shows A06 even when the fan is running correctly. APS failure is the second most common A06 cause.

4
APS connecting hose split

A cracked or disconnected rubber hose between the APS and fan assembly prevents the APS from sensing fan pressure, triggering A06.

5
Blocked condensate trap

A blocked condensate trap restricts the exhaust gas path inside the boiler, creating backpressure that prevents the APS from making correctly.

6
Frozen condensate pipe

In winter, a frozen external condensate pipe creates backpressure that mimics a flue blockage and triggers A06. Thawing the pipe often resolves this immediately.

What you can safely check yourself

1
Check the flue terminal

If the flue terminal is safely visible from ground level, check for obvious blockages — birds, debris, or leaves. Do not reach inside the flue terminal.

2
Thaw condensate in winter

Pour warm (not boiling) water along the external condensate pipe. Once thawed, attempt one reset. This resolves a significant proportion of winter A06 callouts.

3
Single reset attempt

If A06 returns immediately after reset, do not attempt further resets. Call a Gas Safe engineer.

Do not reset the boiler more than once if the fault code returns immediately. Repeated resets without diagnosis can mask a worsening fault.

What needs a Gas Safe engineer

  • Test fan motor speed and current draw with a multimeter
  • Inspect flue terminal and flue run for blockages or restriction
  • Test air pressure switch function and diaphragm integrity
  • Inspect APS connecting hose for splits or disconnection
  • Clear or replace blocked condensate trap
  • Check PCB fan sensing circuit if all other components test correctly
  • Note parts lead time — Ferroli fan motors can be 3–7 days from specialist suppliers

Fan faults are common across South London's older housing stock. Many Ferroli Modena and DOMIproject boilers installed across Wandsworth, Merton, Lewisham, Lambeth, Southwark, Greenwich, and Bromley are now 8–12 years old — within the fan motor wear window. Annual servicing includes a fan speed check. Parts note: some Ferroli fan motors and APS components are 3–7 day lead time from UK suppliers.

[Image placeholder: Gas Safe engineer testing Ferroli fan motor — replace with Reion on-site photo]

How much does a A06 repair cost?

Costs below are UK averages. Reion provides a fixed quote after the £80 diagnostic visit — no obligation to proceed.

Diagnostic visit £80
Fan motor replacement £200–£380
Air pressure switch replacement £80–£160
APS hose replacement £40–£80
Condensate trap clear/replace £60–£100

How to reset a Ferroli boiler showing A06

1

In winter, check and thaw the condensate pipe first.

2

Check the flue terminal for visible blockages from ground level.

3

Press the reset button for 3 seconds.

4

Listen for the fan starting within 5 seconds of reset.

5

If A06 returns, call a Gas Safe engineer.

Fan motor replacement costs £200–£380 all in and is generally worth doing on a Ferroli boiler under 8 years old. However, Ferroli fan motors can carry a 3–7 day parts lead time. On a unit over 8–10 years old with a fan fault, Reion will give a clear repair-vs-replace comparison at the diagnostic visit, factoring in parts availability and the unit's overall condition.

Common questions about the Ferroli A06 fault

What does a Ferroli A06 fault code mean?
A06 means the boiler's PCB did not receive confirmation from the air pressure switch that the fan is running correctly and the flue is clear. Most common causes are a failing fan motor, blocked flue terminal, or faulty air pressure switch.
Can a Ferroli A06 fault be caused by cold weather?
Yes — a frozen condensate pipe creates backpressure that prevents the APS from making. Thawing the condensate pipe with warm water and resetting the boiler often clears A06 in winter without an engineer visit.
How long does a Ferroli A06 repair take in London?
APS or hose replacement takes 60–90 minutes. Fan motor replacement takes 90–150 minutes. However, Ferroli fan motors may require ordering and can take 3–7 days to arrive. Reion covers all South London including Wimbledon, Wandsworth, Merton, Lewisham, Lambeth, Southwark, Greenwich, and Bromley.
Is a Ferroli A06 fault dangerous?
The A06 lockout is a safety mechanism — the boiler has refused to ignite because it cannot confirm safe flue clearance. Do not attempt to override or bypass the lockout.
Why are Ferroli fan parts sometimes slow to source?
Ferroli is an Italian manufacturer with a smaller UK installed base than brands like Vaillant or Worcester Bosch. Some Ferroli-specific components — including fan motors and PCBs — are not held in standard local merchant stock and require ordering from specialist Ferroli parts suppliers, which can take 3–7 working days.

Need a Ferroli engineer in London?

Reion is Gas Safe registered (919881), based in South London, and available 24/7. Fixed price after the diagnostic visit — no hidden charges.

Accreditations & qualifications